Refine
Year of publication
Document Type
- Conference Proceeding (44)
- Lecture (44)
- Article (12)
- Part of a Book (1)
Keywords
- eHealth (30)
- Interoperability (14)
- Education (12)
- Telemonitoring (12)
- Standards (10)
- Electrical Stimulation (9)
- Healthcare (8)
- Standardization (6)
- eLearning (6)
- ELGA (5)
- Health data (5)
- Biosignals (4)
- Lung Simulator (4)
- Electronic Health Records (3)
- Health Applications (3)
- IT Standards (3)
- Muscle Stimulation (3)
- App development (2)
- Blood Glucose (2)
- COVID19 (2)
- Communication Standards (2)
- Digital Healthcare (2)
- Health Device (2)
- ISO (2)
- Knowledge Profiles (2)
- Medical Information Systems (2)
- Mobile Application (2)
- Monitoring (2)
- Personal Health (2)
- Privacy (2)
- Security (2)
- Telehealth (2)
- Virtual Lab (2)
- Amplitude (1)
- Biomedical Engineering (1)
- Bluetooth (1)
- Breathing Simulation (1)
- CEN (1)
- COVID19 Data Sharing (1)
- Clinical Application (1)
- Clinical Data (1)
- Compatibility (1)
- Computer Architecture (1)
- Data (1)
- Data Analysis (1)
- Data Collection (1)
- Data Communication (1)
- Data Transmission (1)
- Decision Making (1)
- Devices (1)
- Diabetes (1)
- Didactics (1)
- Digitalisierung im Krankenhaus (1)
- Electroneurodiagnostics (1)
- Engineering (1)
- Extramural (1)
- FHIR (1)
- Health Interoperability (1)
- Healthy Interoperability (1)
- IEEE (1)
- IEEE standards (1)
- Identity Management (1)
- Intensive Care unit (1)
- Interoperabilität (1)
- Java (1)
- Krankenhaus IT (1)
- Krankenhaus-IT (1)
- Medical Services (1)
- Medical devices (1)
- Medicine (1)
- Mobile Devices (1)
- Muscle Denervation (1)
- Open Data (1)
- PHR (1)
- Problem Based Learning (1)
- QM und Digitalisierung (1)
- Questionnaires (1)
- RFID (1)
- SARS-COV2 (1)
- Smart Grid (1)
- Software (1)
- Stimulator (1)
- Surgery (1)
- Telemedicine (1)
- data sharing (1)
- e-Health (1)
- privacy (1)
- pseudo-anonymization (1)
- statistical disclosure control (1)
- telemedicine (1)
Department
Simulation models in respiratory research are increasingly used for medical product development and testing, especially because in-vivo models are coupled with a high degree of complexity and ethical concerns. This work introduces a respiratory simulation system, which is bridging the gap between the complex, real anatomical environment and the safe, cost-effective simulation methods. The presented electro-mechanical lung simulator, xPULM, combines in-silico, ex-vivo and mechanical respiratory approaches by realistically replicating an actively breathing human lung. The reproducibility of sinusoidal breathing simulations with xPULM was verified for selected breathing frequencies (10–18 bpm) and tidal volumes (400–600 ml) physiologically occurring during human breathing at rest. Human lung anatomy was modelled using latex bags and primed porcine lungs. High reproducibility of flow and pressure characteristics was shown by evaluating breathing cycles (nTotal = 3273) with highest standard deviation |3σ| for both, simplified lung equivalents (μV˙ = 23.98 ± 1.04 l/min, μP = −0.78 ± 0.63 hPa) and primed porcine lungs (μV˙ = 18.87 ± 2.49 l/min, μP = −21.13 ± 1.47 hPa). The adaptability of the breathing simulation parameters, coupled with the use of porcine lungs salvaged from a slaughterhouse process, represents an advancement towards anatomically and physiologically realistic modelling of human respiration.